Easy to program display
Easy to clean the stainless-steel heat exchanger
Quick connect components
Universal vent connections with embedded test port
Vents in PVC, CPVC, or Poly Propylene
MODELS | TX151C | TX200C |
---|---|---|
Input power, DHW | 18.9 - 151 MBH | 24.9 - 199 MBH |
Input power, Heating | 18.9 - 80 MBH | 24.9 - 120 MBH |
AFUE | 95% | 95% |
Heating capacity | 74 MBH | 111 MBH |
Net AHRI Rating | 64 MBH | 96 MBH |
DHW Flow Rate at 77°F T Rise | 3.5 GPM | 4.6 GPM |
Installation type | Indoor Wall Hung (rack available for floor standing installation) | Indoor Wall Hung (rack available for floor standing installation) |
Weight | 98 lb | 120 lb |
Gas connection | 1⁄2 in NPT female | 1⁄2 in NPT female |
Water connections | 1 in female (sweat joint) | 1 in female (sweat joint) |
DHW connections | 3⁄4 in NPT male | 3⁄4 in NPT male |
Air Inlet | 2 in (max 100 ft), 3 in (max 150 ft) | 3 in (max 100 ft) |
Flue | 2 in (max 100 ft), 3 in (max 150 ft) | 3 in (max 100 ft) |
MODEL | TX51 | TX81 | TX101 | TX151 | TX200 |
---|---|---|---|---|---|
Input power | 7.1 - 57 MBH | 10.3 - 82 MBH | 12.6 - 101 MBH | 18.9 - 151 MBH | 24.9 - 199 MBH |
AFUE | 94% | 94% | 94% | 94% | 94% |
Heating capacity | 52 MBH | 75 MBH | 92 MBH | 139 MBH | 184 MBH |
Net AHRI rating | 45 MBH | 65 MBH | 80 MBH | 120 MBH | 160 MBH |
Installation type | Indoor Wall Hung (rack available for floor standing installation) | Indoor Wall Hung (rack available for floor standing installation) | Indoor Wall Hung (rack available for floor standing installation) | Indoor Wall Hung (rack available for floor standing installation) | Indoor Wall Hung (rack available for floor standing installation) |
Weight | 77 lb | 79 lb | 86 lb | 87 lb | 98 lb |
Gas connection | 1⁄2 in NPT female | 1⁄2 in NPT female | 1⁄2 in NPT female | 1⁄2 in NPT female | 1⁄2 in NPT female |
Water connection | 1 in NPT male | 1 in NPT male | 1 in NPT male | 1 in NPT male | 1 in NPT male |
Air inlet | 2 in (max 100 ft), 3 in (max 150 ft) | 2 in (max 100 ft), 3 in (max 150 ft) | 2 in (max 100 ft), 3 in (max 150 ft) | 2 in (max 100 ft), 3 in (max 150 ft) | 3 in (max 100 ft) |
Flue | 2 in (max 100 ft), 3 in (max 150 ft) | 2 in (max 100 ft), 3 in (max 150 ft) | 2 in (max 100 ft), 3 in (max 150 ft) | 2 in (max 100 ft), 3 in (max 150 ft) | 3 in (max 100 ft) |